The Anton Sprint Pro 6 Kit A is the complete reporting kit built around Anton's most advanced analyser. It combines the dedicated NO sensor for NO and NOx measurement with the dual-beam infrared CO₂ sensor for direct ambient CO₂ monitoring alongside simultaneous CO measurement. Kit A adds an infrared printer, gas escape probe, Anton Pressure Relief Valve and two AS10 pipe clamp temperature probes to the base analyser.
Bluetooth connectivity links the analyser to the Anton Sprint Pro mobile app. Kit A also includes a triple filter water trap, giving complete hydrophobic protection from moisture in the field — an upgrade over the standard double water-stop used on other Sprint Pro models. It's independently tested by BSI to EN 50379-1:2012 and EN 50379-3:2012, hydrogen blend ready, and covered by a 2-year warranty.
Kit A can be considered the most capable single kit in the Anton range, intended for professionals conducting commercial catering investigation (COMCAT), CO/CO₂ incident investigation (CMDDA1), and standard combustion testing where every available measurement option is wanted in one purchase.
Note: if testing oil-powered appliances, the Sprint Pro Flue Probe with 3 Micron Filter (C03767/S) is recommended.
Kit A brings the printer, APRV and pipe clamp probes together with the only Sprint Pro analyser offering both NOx sensing and direct ambient CO₂ measurement, giving full on-site reporting capability without sourcing accessories separately. The triple filter water trap adds extra protection beyond the standard double water-stop, useful for the more demanding field conditions commercial and incident investigation work can involve.
Order the Anton Sprint Pro 6 Multifunction Flue Gas Analyser Kit A online today.
| Brand | Anton |
|---|---|
| Product Type | Multifunction Flue Gas Analyser – NO/NOx + Direct CO₂ (Full Spec) |
| CO | Direct electrochemical measurement |
| CO₂ (flue) | Calculated (0–21%, 0.1% resolution, ±0.3%) |
| CO₂ (ambient — direct IR) | Dual-beam infrared sensor – simultaneous CO/CO₂ monitoring |
| NO/NOx | Direct measurement via dedicated NO sensor |
| Flue Temperature | 5°C – 400°C | 1°C | ±2°C or 1.5% of reading |
| K-Type Thermocouple | -50°C to 1000°C | ±2°C or 1.5% of reading |
| Differential Pressure | 0–400 mbar | 0.01 mbar | ±0.5 mbar or 1% |
| Draught Measurement | Yes |
| Gas Leak Detection | Included – Anton Gas Pro Detector with LED searchlight |
| Wireless Connectivity | Wi-Fi – Anton Sprint Pro Mobile app (iOS and Android) |
| Standards | EN 50379-1:2012, EN 50379-3:2012 (BSI tested), BS 7967, BS 8494 |
| Hose Length | 2.146m |
| Insertion Length | 250mm |
| Fuel Options | Natural gas, LPG, heavy oil, light oil, coal, wood, wood pellets, coke, biomass, bagasse |
| Battery | Li-ion rechargeable, USB-C, up to 14 hours |
| Operating Temperature | -10°C to +50°C |
| Dimensions (Analyser) | H 183 × W 85 × D 50mm |
| Weight | 490g |
| Hydrogen Ready | Yes |
| Lead Time | Made to order – typically 2–3 weeks. Contact us for exact date. |
| Warranty | 2 years |