Rinnai PA-KIT E (NG) A Series Gas Control Assembly - (PA-KIT E (NG))

The PA-KIT E (NG) is the genuine Rinnai gas control assembly for the A Series Infinity, specific to Natural Gas installations. It bundles the main solenoid valve, the changeover solenoid valves, and the modulating valve into a single assembly. The main solenoid stays open as long as there's flow through the unit, while the modulating valve and changeover solenoids manage the gas flow rate to keep water temperature stable regardless of demand or flow rate. The valve is electronically controlled and factory set, so no adjustment is normally needed during installation — unless the unit isn't performing correctly and every other cause has been ruled out.

After fitting this assembly, gas pressure needs verifying and setting at the burner test point, following Rinnai's commissioning procedure across both high and low combustion modes.

This assembly is strictly for Natural Gas installations. Fitting it to an LPG system will result in incorrect combustion and safety issues, so confirm the gas type before ordering.

⚠ Important: This is gas-carrying, safety-critical equipment. Installation and any related maintenance must only be carried out by a Gas Safe registered engineer.

Key Features & Benefits
  • Genuine Rinnai OEM for Natural Gas: Manufactured to Rinnai's original specification for the A Series NG version.
  • All-in-One Gas Control Assembly: Combines the main solenoid, changeover solenoid, and modulating valve in one component.
  • PCB-Controlled Modulation: The modulating valve adjusts gas flow under PCB control to keep water temperature stable regardless of flow rate.
  • Pre-Set Electronic Gas Control: Factory set to Rinnai's specification, with gas pressure verification the only routine post-installation check.
  • Dual Safety Cut-Off Valve: The main solenoid shuts off gas flow immediately when instructed by the PCB or in a fault condition.
Ideal For
  • Rinnai Infinity A Series Natural Gas installations.
  • A Series units with ignition, combustion, or water temperature faults.
  • Diagnosing fault code 52 or 71 once wiring has been ruled out.
  • Gas engineers investigating and repairing A Series faults.
  • Natural Gas installations only – not for LPG.
Common Problems This Part Will Fix
  • No Gas Reaching the Burner: Where supply, pressure, and ignition spark have already been confirmed as sound.
  • Fault Code 52: Modulating valve losing its control signal.
  • Fault Code 71: Solenoid valve circuit fault.
  • Solenoid Valve Not Holding Pressure: Resistance readings outside the expected range on testing.
  • Unstable Water Temperature: Modulating valve failing to regulate gas flow correctly against demand.
  • Burner Won't Stay Lit: Solenoid valve failing to hold pressure after initial ignition.
Why Buy This Product?

If your A Series unit is throwing fault code 52 or 71 after wiring has already been ruled out, or you're seeing ignition, combustion, or temperature stability problems that don't trace back to anywhere else, this assembly is very likely the fix. It replaces the main solenoid, changeover solenoids, and modulating valve as one unit, so you're restoring precise gas control across the whole system rather than patching one component and hoping the rest holds.

Order the Rinnai PA-KIT E (NG) A Series Gas Control Assembly online today.

Specification

Rinnai PA-KIT E (NG) A Series Gas Control Assembly - Genuine Spare Specification

Manufacturer Rinnai
Part Number PA-KIT E (NG)
Product Type Gas Control Assembly
Gas Type Natural Gas (NG) – Not Suitable for LPG
Compatible Range Rinnai Infinity A Series Continuous Flow Water Heaters
Assembly Contents Main Solenoid Valve, Changeover Solenoid Valves, Electronically Controlled Modulating Valve
Control Electronically Controlled by PCB via Sensor Inputs
Function Controls All Gas Delivery to the Burner for Temperature-Accurate Continuous Flow Operation
Post-Installation Requirement Gas Pressure Verification and Setting Required Following Replacement
Installation Gas Safe Registered Engineer Required
Features

Rinnai PA-KIT E (NG) A Series Gas Control Assembly - Genuine Spare Features

  • Genuine Rinnai OEM for Natural Gas: Manufactured to Rinnai's original specification for the A Series NG version.
  • All-in-One Gas Control Assembly: Combines the main solenoid, changeover solenoid, and modulating valve in one component.
  • PCB-Controlled Modulation: The modulating valve adjusts gas flow under PCB control to keep water temperature stable regardless of flow rate.
  • Pre-Set Electronic Gas Control: Factory set to Rinnai's specification, with gas pressure verification the only routine post-installation check.
  • Dual Safety Cut-Off Valve: The main solenoid shuts off gas flow immediately when instructed by the PCB or in a fault condition.