Regin Thermocouple Tester

In stock
SKU
REGT20
£24.30 £20.25
Or 3 Interest-Free Payments of £8.10
apple pay
klarna
google pay
paypal
chevron-up
Description

Regin Thermocouple Tester (REGT20)

When a gas appliance’s pilot keeps going out, the thermocouple is the usual suspect, but swapping parts to find out is slow. The Regin REGT20 lets you test a thermocouple on its own, off the appliance, by simulating the way a gas valve holds open.

To test, assemble the thermocouple into the tester, heat the tip and press the white button. If the thermocouple is working correctly, the plunger stays down for approximately 20 to 30 seconds, simulating the holding action of a gas valve. If it doesn’t, the thermocouple is the likely fault.

Use a suitable heat source and take care when heating the tip. The tester checks the thermocouple only, so a pass doesn’t replace checks on the appliance. Work on gas appliances must be carried out by a suitably qualified, registered gas installer in accordance with the relevant standards.

Key Features & Benefits
  • Tests a Thermocouple on Its Own: No need to fit a new one to find out.
  • Simulates a Gas Valve: The plunger holds down like a gas valve would.
  • Simple Go/No-Go Result: The plunger stays down for about 20 to 30 seconds if it's working.
  • Simple Operation: Assemble, heat the tip and press the button.
  • Handheld: Small enough for a toolbox or van.
Ideal For
  • Heating and gas engineers diagnosing pilot and flame failure faults.
  • Checking a thermocouple before replacing it.
  • Toolkits and service vans.
Why Buy This Product?

Testing a thermocouple takes seconds with this tester, and it saves swapping parts to find a fault. It’s simple, handheld and cheap enough to keep in the van.

Order the Regin Thermocouple Tester online today.

Specification

Regin Thermocouple Tester Specification

Brand Regin
Model REGT20
Product Type Thermocouple Tester
Function Tests Thermocouple Operation by Simulating a Gas Valve
Operation Manual: Assemble the Thermocouple, Heat the Tip, Press the White Button
Pass Result Plunger Stays Depressed for Approx. 20 to 30 Seconds
Format Handheld
Suitable Users Heating and Gas Engineers (Registered Gas Installers for Appliance Work)
Features

Regin Thermocouple Tester Features

  • Tests a Thermocouple on Its Own: No need to fit a new one to find out.
  • Simulates a Gas Valve: The plunger holds down like a gas valve would.
  • Simple Go/No-Go Result: The plunger stays down for about 20 to 30 seconds if it's working.
  • Simple Operation: Assemble, heat the tip and press the button.
  • Handheld: Small enough for a toolbox or van.